This document presents the RF exposure compliance report for a portable device with FCC ID 2ALGY-23043. The report assesses the device's adherence to FCC guidelines, ensuring that public exposure to radio frequency energy remains within safe limits. The evaluation is based on §15.247(e)(i) and §1.1307(b)(1) of FCC regulations, as well as KDB447498 D01 General RF Exposure Guidance V06.
The report focuses on SAR (Specific Absorption Rate) test exclusion thresholds for frequencies between 100 MHz and 6 GHz, with test separation distances of ≤ 50 mm. The calculations are based on the formula provided in the guidelines, considering the maximum power of the channel, including tune-up tolerance, and the minimum test separation distance. The results are presented for both BLE:1M and BLE:2M modes, demonstrating compliance with the 1-g SAR limit of 3.0. The conclusion confirms that the maximum result (0.49918) is below the FCC limit, indicating that the device meets the RF exposure requirements.