Morlab System Performance Check: Annex C Plots

AnnexC

This document presents the Annex C plots from a system performance check conducted by Morlab Communications Technology Co., Ltd. The check was performed on February 14, 2025, using a 2450MHz head setup. The report details the configuration of the DASY5 system, including the probe model (ES3DV3 SN3295), electronics (DAE4 Sn1324), and phantom type (SAM 1 QD000P40CD Serial 1811). The measurement software used was DASY52, Version 52.10 (4), with SEMCAD X Version 14.6.14 (7501).

The document includes the area scan and zoom scan results, providing interpolated SAR values and peak SAR extrapolation. Specific SAR values for 1g and 10g are reported, along with the distance from peaks to all points 3 dB below. The ratio of SAR at M2 to SAR at M1 is also provided. The report concludes with the maximum value of SAR measured.


File Info : application/pdf, 2 Pages, 333.00KB

Download
Microsoft Office Word 2007
tags: ["SZ25010154S01", "ES3DV3", "SN3295", "DAE4", "Sn1324", "QD000P40CD", "1811", "DASY52", "2450MHz"]
Array
(
    [0] => Array
        (
            [url_sha] => ed568c86b833b5f22733a64a1372d3a28daf328139c2c47aaeca00686e7309a9
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8100586
            [href_text] => AnnexC
            [href_description] => Realme Chongqing Mobile Telecommunications Corp., Ltd. RMA2412 Earphone 2AUYFRMA2412 2AUYFRMA2412 rma2412
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => application/pdf
            [http_filename] => GetApplicationAttachment.html?id=8100586
            [http_size] => 340987
            [file_sha256] => 51e11e47f45c08d4563e32e75fa3ba97564b933d25a2229e646abeed6ef3584a
            [domain] => document.fccid
        )

    [1] => Array
        (
            [url_sha] => c95b4d696cab14feadac8810fc2ef2f240be9af98e75997299df62759424dc1c
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8100610
            [href_text] => AnnexC
            [href_description] => Realme Chongqing Mobile Telecommunications Corp., Ltd. RMA2412 Earphone 2AUYFRMA2412 2AUYFRMA2412 rma2412
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => application/pdf
            [http_filename] => GetApplicationAttachment.html?id=8100610
            [http_size] => 340987
            [file_sha256] => 51e11e47f45c08d4563e32e75fa3ba97564b933d25a2229e646abeed6ef3584a
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => 51e11e47f45c08d4563e32e75fa3ba97564b933d25a2229e646abeed6ef3584a
    [cleanFccId] => 2AUYFRMA2412
    [title] => Morlab System Performance Check: Annex C Plots
    [description] => System performance check plots for 2450MHz head. Includes configuration details, SAR values, and measurement parameters. Morlab report.
    [brand_name] => Morlab
    [keywords] => ["SZ25010154S01", "ES3DV3", "SN3295", "DAE4", "Sn1324", "QD000P40CD", "1811", "DASY52", "2450MHz"]
    [intro] => 

This document presents the Annex C plots from a system performance check conducted by Morlab Communications Technology Co., Ltd. The check was performed on February 14, 2025, using a 2450MHz head setup. The report details the configuration of the DASY5 system, including the probe model (ES3DV3 SN3295), electronics (DAE4 Sn1324), and phantom type (SAM 1 QD000P40CD Serial 1811). The measurement software used was DASY52, Version 52.10 (4), with SEMCAD X Version 14.6.14 (7501).

The document includes the area scan and zoom scan results, providing interpolated SAR values and peak SAR extrapolation. Specific SAR values for 1g and 10g are reported, along with the distance from peaks to all points 3 dB below. The ratio of SAR at M2 to SAR at M1 is also provided. The report concludes with the maximum value of SAR measured.

)
Array
(
    [0] => Array
        (
            [id] => 8100586
            [file_sha256] => 
            [applicationId] => gEWM2H+2q4IFvNg9wobaRQ==
            [description] => AnnexC
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => RF Exposure Info
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 340989
            [submissionDate] => 2025-03-07 00:00:00
            [dateAvailable] => 2025-03-07 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 1
            [source] => 0
            [fccId] => 2AUYFRMA2412
            [cleanFccId] => 2AUYFRMA2412
            [exif] => 0
        )

)