This test report, issued by Shenzhen Huaxia Testing Technology Co., Ltd., details the compliance testing of the Diagnostic Tools product line manufactured by Changsha Angsi E-commerce Co., Ltd. The tested models include DeepScan, DeepScan Lite, DeepScan Pro, DeepScan Master, and DeepScan Max, all operating within the 2402MHz to 2480MHz frequency range using Bluetooth V5.0 technology.
The report confirms that the EUT (Equipment Under Test) complies with the standards specified in 47 CFR Part 15, Subpart C, KDB558074 D01, and ANSI C63.10:2013. Key tests performed include conducted peak output power, 20dB occupied bandwidth, carrier frequencies separation, hopping channel number, dwell time, band-edge for RF conducted emissions, spurious RF conducted emissions, and radiated spurious emission. The FCC ID for the device is 2BNZ7-DSCAN.
The testing was conducted between March 14, 2025, and March 26, 2025, with the report issued on April 15, 2025. The test results indicate that the EUT passed all specified tests, demonstrating compliance with the relevant regulatory requirements.
Array ( [0] => Array ( [url_sha] => 3d2ccf8a6cab5caea6778abb2c7c7f9742c29b57491ec7cea6a600d79de13a0e [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8255908 [href_text] => Test Report [href_description] => Changsha Angsi E-commerce Co., Ltd. DSCAN Diagnostic Tools 2BNZ7-DSCAN 2BNZ7DSCAN dscan [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => [http_filename] => GetApplicationAttachment.html?id=8255908 [http_size] => 4960505 [file_sha256] => 4db956cff60539420c302dd7209ebc483a9d5ec2a69518858fc0cab37bb9397c [domain] => document.fccid ) ) Array ( [file_sha256] => 4db956cff60539420c302dd7209ebc483a9d5ec2a69518858fc0cab37bb9397c [cleanFccId] => 2BNZ7DSCAN [title] => Diagnostic Tools Test Report by Shenzhen Huaxia Testing [description] => This test report details the compliance of Diagnostic Tools with FCC standards, conducted by Shenzhen Huaxia Testing Technology Co., Ltd. [brand_name] => DeepScan [keywords] => ["Diagnostic Tools", "DeepScan", "DeepScan Lite", "DeepScan Pro", "DeepScan Master", "DeepScan Max", "2BNZ7-DSCAN", "KDB558074 D01", "ANSI C63.10:2013", "47 CFR Part 15, Subpart C", "CQASZ20250300543E-01"] [intro] =>This test report, issued by Shenzhen Huaxia Testing Technology Co., Ltd., details the compliance testing of the Diagnostic Tools product line manufactured by Changsha Angsi E-commerce Co., Ltd. The tested models include DeepScan, DeepScan Lite, DeepScan Pro, DeepScan Master, and DeepScan Max, all operating within the 2402MHz to 2480MHz frequency range using Bluetooth V5.0 technology.
The report confirms that the EUT (Equipment Under Test) complies with the standards specified in 47 CFR Part 15, Subpart C, KDB558074 D01, and ANSI C63.10:2013. Key tests performed include conducted peak output power, 20dB occupied bandwidth, carrier frequencies separation, hopping channel number, dwell time, band-edge for RF conducted emissions, spurious RF conducted emissions, and radiated spurious emission. The FCC ID for the device is 2BNZ7-DSCAN.
The testing was conducted between March 14, 2025, and March 26, 2025, with the report issued on April 15, 2025. The test results indicate that the EUT passed all specified tests, demonstrating compliance with the relevant regulatory requirements.
)
Array ( [0] => Array ( [id] => 8255908 [file_sha256] => [applicationId] => 4NRjUnKu10u3LRwUU0rQbQ== [description] => Test Report [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => Test Report [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 2479269 [submissionDate] => 2025-04-30 00:00:00 [dateAvailable] => 2025-05-05 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => 2BNZ7-DSCAN [cleanFccId] => 2BNZ7DSCAN [exif] => 0 ) )