This FCC MPE (Maximum Permissible Exposure) report summarizes the radiation hazard testing performed on a Midea microwave oven, model EMB34G5MA-S. The testing was conducted by CCIC Southern Testing Co., Ltd. to ensure compliance with FCC regulations and standards, specifically FCC/OST MP-5(1986) and OET Bulletin 56(1999).
The report details the test setup, procedure, and limits for radiation leakage. The microwave oven was tested in its as-received condition with a water load, and radiation leakage was measured using a microwave leakage meter. The results indicate that the microwave oven meets the FCC's radiation safety standards, with no leakage exceeding the permissible limit of 1.0 mW/cm². The maximum leakage observed was 0.41 mW/cm² at the front of the oven, well below the regulatory limit.
The report includes information about the testing facilities, equipment used, and environmental conditions during the tests. It also provides a test setup photo and the contact information for CCIC Southern Testing Co., Ltd.