DASY5 Validation Report: Dipole Calibration for Head TSL

BEJTFJLEENN5E3_Appendix F,G_Calibration Data_FCC_R3_6 of 6

This document presents a comprehensive DASY5 validation report for head tissue simulating liquid (TSL), focusing on dipole calibration. Conducted by SPEAG in Zurich, Switzerland, the report details the calibration of dipoles at 3500 MHz, 3700 MHz and 3900 MHz. The report includes detailed information about the measurement setup, including the DASY52 configuration, probe specifications (EX3DV4 - SN3503), electronics (DAE4 Sn601 and Sn781), and phantom details (Flat Phantom 5.0). The calibration process adheres to IEEE/IEC/ANSI C63.19-2011 standards.

Key parameters such as SAR (Specific Absorption Rate) values, including SAR(1 g) and SAR(10 g), are meticulously measured and reported. Antenna parameters, including impedance and return loss, are also assessed. The report provides a detailed analysis of the dipole's performance under specific conditions, ensuring its suitability for accurate SAR measurements. The document includes graphical representations of SAR distribution and impedance measurement plots, offering a visual understanding of the dipole's characteristics. This report is essential for validating the accuracy and reliability of SAR testing procedures.


File Info : application/pdf, 14 Pages, 4.41MB

Download
Microsoft Word 2016
SPEAG: D3500V2, D3500V2 - SN:1132, D3700V2, D3700V2-1105, D3900V2, D3900V2 SN:1086, EX3DV4, SN3503, DAE4, Sn601, Sn781, HCT-SR-2503-FC003-R3, SCS 0108