This document presents an RF exposure evaluation report for a device manufactured by GTS. The evaluation is conducted in accordance with the guidelines outlined in 447498 D04 Interim General RF Exposure Guidance v01 and ANSI C63.10 standards. The report aims to determine whether the device complies with the established RF exposure limits and if a Specific Absorption Rate (SAR) evaluation is necessary.
The evaluation considers factors such as frequency, field strength, and ERP (Effective Radiated Power). Power thresholds are calculated based on formulas and tables provided in the guidelines. The report includes specific measurements and calculations for the device, including field strength measurements at a frequency of 2445.00 MHz. The results indicate that the ERP value is -5.08dBm, which is below the established limit. Therefore, based on the evaluation, a SAR evaluation is not required for this device.
Array ( [0] => Array ( [url_sha] => a491ffc30df1a462f137c6451bb224a9fd23127e762c79e26c6ede86c2dfd548 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8056594 [href_text] => RF EXPO [href_description] => QIJUN TOYS INDUSTRY CO.,LIMITED 18422 2A5IA-18422 2A5IA18422 18422 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8056594 [http_size] => 126899 [file_sha256] => 3914c91e27fdcd874017704c0a77bedc9952a26dcc5a9fffff0cd6a34f214480 [domain] => document.fccid ) ) Array ( [file_sha256] => 3914c91e27fdcd874017704c0a77bedc9952a26dcc5a9fffff0cd6a34f214480 [cleanFccId] => 2A5IA18422 [title] => RF Exposure Evaluation Report for GTS Device 2A5IA-18422 [description] => This report evaluates RF exposure compliance based on ANSI C63.10 and 447498 D04 guidelines. SAR evaluation is not required. [brand_name] => GTS [keywords] => ["RF Exposure", "ANSI C63.10", "447498 D04", "2A5IA-18422"] [intro] =>This document presents an RF exposure evaluation report for a device manufactured by GTS. The evaluation is conducted in accordance with the guidelines outlined in 447498 D04 Interim General RF Exposure Guidance v01 and ANSI C63.10 standards. The report aims to determine whether the device complies with the established RF exposure limits and if a Specific Absorption Rate (SAR) evaluation is necessary.
The evaluation considers factors such as frequency, field strength, and ERP (Effective Radiated Power). Power thresholds are calculated based on formulas and tables provided in the guidelines. The report includes specific measurements and calculations for the device, including field strength measurements at a frequency of 2445.00 MHz. The results indicate that the ERP value is -5.08dBm, which is below the established limit. Therefore, based on the evaluation, a SAR evaluation is not required for this device.
)
Array ( [0] => Array ( [id] => 8056594 [file_sha256] => [applicationId] => YAvqxoiAiA0U0/JEy3BhTA== [description] => RF EXPO [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 126899 [submissionDate] => 2025-02-19 00:00:00 [dateAvailable] => 2025-02-19 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => 2A5IA-18422 [cleanFccId] => 2A5IA18422 [exif] => 0 ) )