RF Exposure Evaluation Report for QA24R5SU16512 ALL IN ONE

HTT202505429F05_RF Exposure-info

This document presents the RF exposure evaluation report for the QA24R5SU16512 ALL IN ONE device manufactured by M&M Electronics, S.A. The evaluation was conducted by Shenzhen HTT Technology Co., Ltd. to ensure compliance with FCC regulations regarding radio frequency exposure limits.

The report details the testing environment, applicable standards (including ANSI C95.1–1999, FCC KDB 447498 D01, FCC CFR 47 part 1.1310, and FCC CFR 47 part 2.1093), and the test results. The device supports various wireless technologies, including BT, BLE, 2.4GHz WiFi, and 5GHz WiFi, each operating within specified frequency ranges and modulation schemes. The report includes conducted power measurements for each technology and antenna, along with an evaluation of simultaneous transmission scenarios.

The evaluation concludes that the device meets the SAR test exclusion thresholds as defined in KDB447498 D01, indicating that standalone SAR testing is not required. The report provides a comprehensive assessment of the device's RF exposure characteristics, ensuring its safe operation within established regulatory limits.


File Info : application/pdf, 11 Pages, 387.03KB

Download
Microsoft Word 2021 Microsoft Word 2021
M&M Electronics: QA24R5SU16512, ALL IN ONE, HTT202505429F05, 2BLU9-QA24R5SU, FCC CFR 47 part1 1.1310, FCC CFR 47 part2 2.1093, KDB447498 D01