This document presents the RF Exposure Evaluation for a device with FCC ID 2A27V-P6. The evaluation is conducted in accordance with KDB 447498 D01 General RF Exposure Guidance v06 and part 2.1093, ensuring compliance with FCC regulations regarding human exposure to radio frequency electromagnetic fields.
The evaluation determines whether standalone 1-g head or body and 10-g extremity Specific Absorption Rate (SAR) evaluation is required for general population exposure conditions. This determination is based on whether the device meets the SAR Test Exclusion Threshold conditions. For devices operating between 100 MHz and 6 GHz with test separation distances of ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are calculated using a specific formula involving the maximum power of the channel, tune-up tolerance, minimum test separation distance, and the RF channel transmit frequency.
The document provides specific data for the 8DPSK mode, including frequency, maximum power, target power, tune-up tolerance, power in mW, minimum distance, calculated thresholds, and the limit. The calculations demonstrate that the SAR test is not required, as the calculated thresholds are below the specified limit.
Array ( [0] => Array ( [url_sha] => f164c2745314367a6e122771244294b3d4613876eb9c99d6a42868d60545464c [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8063556 [href_text] => MPE [href_description] => Dongguan Genai Technology Co.,LTD P6 WirelessEarphones 2A27V-P6 2A27VP6 p6 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8063556 [http_size] => 105992 [file_sha256] => 302a8c269dcb450ba3426b110f632779b47c8571d70acda00eb01ffcafb53c26 [domain] => document.fccid ) ) Array ( [file_sha256] => 302a8c269dcb450ba3426b110f632779b47c8571d70acda00eb01ffcafb53c26 [cleanFccId] => 2A27VP6 [title] => RF Exposure Evaluation Report for FCC ID: 2A27V-P6 [description] => RF Exposure Evaluation report according to KDB 447498 D01. SAR test exclusion thresholds are determined and calculated. [brand_name] => [keywords] => ["2A27V-P6", "RF Exposure", "SAR", "KDB 447498 D01", "8DPSK"] [intro] =>This document presents the RF Exposure Evaluation for a device with FCC ID 2A27V-P6. The evaluation is conducted in accordance with KDB 447498 D01 General RF Exposure Guidance v06 and part 2.1093, ensuring compliance with FCC regulations regarding human exposure to radio frequency electromagnetic fields.
The evaluation determines whether standalone 1-g head or body and 10-g extremity Specific Absorption Rate (SAR) evaluation is required for general population exposure conditions. This determination is based on whether the device meets the SAR Test Exclusion Threshold conditions. For devices operating between 100 MHz and 6 GHz with test separation distances of ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are calculated using a specific formula involving the maximum power of the channel, tune-up tolerance, minimum test separation distance, and the RF channel transmit frequency.
The document provides specific data for the 8DPSK mode, including frequency, maximum power, target power, tune-up tolerance, power in mW, minimum distance, calculated thresholds, and the limit. The calculations demonstrate that the SAR test is not required, as the calculated thresholds are below the specified limit.
)
Array ( [0] => Array ( [id] => 8063556 [file_sha256] => [applicationId] => rWGKhXA4fYBQzl6A/4YgDQ== [description] => MPE [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 105993 [submissionDate] => 2025-02-21 00:00:00 [dateAvailable] => 2025-02-21 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => 2A27V-P6 [cleanFccId] => 2A27VP6 [exif] => 0 ) )