This document presents an RF exposure evaluation for a device with FCC ID 2BFS3-5050-24V, conducted to ensure compliance with Federal Communications Commission (FCC) guidelines. The evaluation adheres to §1.1307(b)(1) and §2.1093 of the FCC regulations, as well as the KDB447498 v06 document, which outlines procedures for mobile and portable devices' RF exposure and equipment authorization policies.
The evaluation focuses on standalone SAR test exclusion considerations, as detailed in KDB447498 D01 Section 4.3.1. The report determines whether SAR testing is required based on the device's output power, operating frequency, and minimum test separation distance. The calculations and results presented demonstrate that the device meets the SAR test exclusion thresholds, indicating that it operates within safe RF exposure limits for the general population. The report concludes that the device complies with FCC regulations regarding uncontrolled RF exposure and SAR exclusion thresholds.
Array ( [0] => Array ( [url_sha] => 70b5c82354af6607d4a0c93413a47592927ac6ca80f726696529e0b91649d5cf [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8086974 [href_text] => RF Exposure info [href_description] => Zhongshan Fenglin Lighting Technology Co., Ltd 5050-24V LED strip 2BFS3-5050-24V 2BFS3505024V 5050 24v [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8086974 [http_size] => 142775 [file_sha256] => 2af212c46e074a655b8a6347ef2f168a311730f65e998120660b4ea0c2775350 [domain] => document.fccid ) ) Array ( [file_sha256] => 2af212c46e074a655b8a6347ef2f168a311730f65e998120660b4ea0c2775350 [cleanFccId] => 2BFS3505024V [title] => RF Exposure Evaluation Report for FCC ID: 2BFS3-5050-24V [description] => This report evaluates RF exposure compliance for the device with FCC ID 2BFS3-5050-24V, ensuring it meets FCC guidelines and SAR test exclusion thresholds. [brand_name] => N/A [keywords] => ["2BFS3-5050-24V", "5050-24V", "RF Exposure", "SAR", "KDB447498 v06", "\u00a71.1307(b)(1)", "\u00a71.1310", "\u00a72.1093"] [intro] =>This document presents an RF exposure evaluation for a device with FCC ID 2BFS3-5050-24V, conducted to ensure compliance with Federal Communications Commission (FCC) guidelines. The evaluation adheres to §1.1307(b)(1) and §2.1093 of the FCC regulations, as well as the KDB447498 v06 document, which outlines procedures for mobile and portable devices' RF exposure and equipment authorization policies.
The evaluation focuses on standalone SAR test exclusion considerations, as detailed in KDB447498 D01 Section 4.3.1. The report determines whether SAR testing is required based on the device's output power, operating frequency, and minimum test separation distance. The calculations and results presented demonstrate that the device meets the SAR test exclusion thresholds, indicating that it operates within safe RF exposure limits for the general population. The report concludes that the device complies with FCC regulations regarding uncontrolled RF exposure and SAR exclusion thresholds.
)
Array ( [0] => Array ( [id] => 8086974 [file_sha256] => [applicationId] => /k9KtpeESbox9nJh8YC7uw== [description] => RF Exposure info [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 142775 [submissionDate] => 2025-03-03 00:00:00 [dateAvailable] => 2025-03-03 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => 2BFS3-5050-24V [cleanFccId] => 2BFS3505024V [exif] => 0 ) )