CardioMessenger Smart 4G SAR Test Report

QRI-CMSMART4GWW2_SAR

This test report details the Specific Absorption Rate (SAR) evaluation of the Biotronik CardioMessenger Smart 4G portable device. The device, identified by model name CardioMessenger Smart 4G and FCC ID QRI-CMSMART4GWW2, was tested for compliance with FCC and ISED radio frequency exposure limits. The testing was conducted by cetecom advanced GmbH, an accredited testing laboratory, following IEC/IEEE 62209-1528-2020 and RSS-102 Issue 6 standards.

The report includes comprehensive information on the test setup, measurement system, tissue simulating liquids, and detailed test results for GSM, LTE FDD bands. Conducted power measurements and SAR test results are presented, along with uncertainty analysis and system validation data. The maximum SAR values reported are below the specified limits for general population/uncontrolled exposure. The report also includes standalone SAR test exclusion analysis and multiple transmitter information.

The test results demonstrate that the CardioMessenger Smart 4G complies with the applicable RF exposure limits, ensuring safe operation for users. The report provides a complete record of the testing process and results, supporting the device's regulatory compliance.


File Info : application/pdf, 66 Pages, 1.83MB

Download
Microsoft Word 2016
tags: ["CardioMessenger Smart 4G", "CMSMART4GWW2", "QRI-CMSMART4GWW2", "4708A-CMSMART4GWW2", "ME910G1-WW"]
Array
(
    [0] => Array
        (
            [url_sha] => 00a5b41e1dfe3116e7383c5f0d9db255b8a79f97d1886d37ceeb5469775b3688
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8307532
            [href_text] => QRI-CMSMART4GWW2_SAR
            [href_description] => BIOTRONIK SE & Co. KG CMSMART4GWW2 CardioMessenger Smart / Telemonitoring System QRI-CMSMART4GWW2 QRICMSMART4GWW2 cmsmart4gww2
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => 
            [http_filename] => GetApplicationAttachment.html?id=8307532
            [http_size] => 1922870
            [file_sha256] => 25f03b570466097e642e9e3ecf4eb22dbbf65f817318201d61380f4ac354fb4a
            [domain] => document.fccid
        )

    [1] => Array
        (
            [url_sha] => 359b4d200f38c8bdec58eabad369826dd6427b557a6f8176b4414c57397083a6
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8307557
            [href_text] => QRI-CMSMART4GWW2_SAR
            [href_description] => BIOTRONIK SE & Co. KG CMSMART4GWW2 CardioMessenger Smart / Telemonitoring System QRI-CMSMART4GWW2 QRICMSMART4GWW2 cmsmart4gww2
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => 
            [http_filename] => GetApplicationAttachment.html?id=8307557
            [http_size] => 1922870
            [file_sha256] => 25f03b570466097e642e9e3ecf4eb22dbbf65f817318201d61380f4ac354fb4a
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => 25f03b570466097e642e9e3ecf4eb22dbbf65f817318201d61380f4ac354fb4a
    [cleanFccId] => QRICMSMART4GWW2
    [title] => CardioMessenger Smart 4G SAR Test Report
    [description] => SAR test report for the CardioMessenger Smart 4G portable device, including test results, standards, and equipment used. Compliant with FCC and ISED regulations.
    [brand_name] => Biotronik
    [keywords] => ["CardioMessenger Smart 4G", "CMSMART4GWW2", "QRI-CMSMART4GWW2", "4708A-CMSMART4GWW2", "ME910G1-WW"]
    [intro] => 

This test report details the Specific Absorption Rate (SAR) evaluation of the Biotronik CardioMessenger Smart 4G portable device. The device, identified by model name CardioMessenger Smart 4G and FCC ID QRI-CMSMART4GWW2, was tested for compliance with FCC and ISED radio frequency exposure limits. The testing was conducted by cetecom advanced GmbH, an accredited testing laboratory, following IEC/IEEE 62209-1528-2020 and RSS-102 Issue 6 standards.

The report includes comprehensive information on the test setup, measurement system, tissue simulating liquids, and detailed test results for GSM, LTE FDD bands. Conducted power measurements and SAR test results are presented, along with uncertainty analysis and system validation data. The maximum SAR values reported are below the specified limits for general population/uncontrolled exposure. The report also includes standalone SAR test exclusion analysis and multiple transmitter information.

The test results demonstrate that the CardioMessenger Smart 4G complies with the applicable RF exposure limits, ensuring safe operation for users. The report provides a complete record of the testing process and results, supporting the device's regulatory compliance.

)
Array
(
    [0] => Array
        (
            [id] => 8307532
            [file_sha256] => 
            [applicationId] => nocjR0XW2TYSnT3Sk6XeSg==
            [description] => QRI-CMSMART4GWW2_SAR
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => RF Exposure Info
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 1922872
            [submissionDate] => 2025-05-20 00:00:00
            [dateAvailable] => 2025-05-20 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 1
            [source] => 0
            [fccId] => QRI-CMSMART4GWW2
            [cleanFccId] => QRICMSMART4GWW2
            [exif] => 0
        )

)