This document presents the detailed system check results conducted by LCS-SAR Lab, as part of the testing and certification process. The report, identified by number LCSA01025170EB, includes performance checks for various frequencies, specifically focusing on head measurements. The frequencies tested include 750 MHz, 835 MHz, 1750 MHz, 1900 MHz, 2450 MHz, and 2600 MHz. The document outlines the testing parameters, equipment used, and the resulting SAR (Specific Absorption Rate) values obtained during the system performance checks.
The equipment used in the tests includes models such as D750V3, D835V2, D1750V2, D1900V2, D2450V2, and D2600V2. The report provides detailed configurations and measurements, including area scans and zoom scans, to ensure the accuracy and reliability of the SAR assessments. The results are crucial for verifying the compliance of devices with regulatory safety standards.
Array ( [0] => Array ( [url_sha] => 00e65644283b7d72f6d2439fff37b3532aecfc32290e63435f284e7440645705 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8265476 [href_text] => Appendix A Detailed System Check Results [href_description] => SWAGTEK 665024 4G Smart Phone O55665024 O55665024 665024 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => [http_filename] => GetApplicationAttachment.html?id=8265476 [http_size] => 321918 [file_sha256] => 2588c810fdb882e9a2b71d70be5a9caaa0bd6abbd38a3b093818ee852f4658a2 [domain] => document.fccid ) [1] => Array ( [url_sha] => efb678e7a38e39764d6fdd4b2f09bd59255141350f0e88312d05383a81f718db [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8265016 [href_text] => Appendix A Detailed System Check Results [href_description] => SWAGTEK 665024 4G Smart Phone O55665024 O55665024 665024 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => [http_filename] => GetApplicationAttachment.html?id=8265016 [http_size] => 321918 [file_sha256] => 2588c810fdb882e9a2b71d70be5a9caaa0bd6abbd38a3b093818ee852f4658a2 [domain] => document.fccid ) [2] => Array ( [url_sha] => 70c58b22a857044a4ab8ac1a8ba59068a28c05e5b8a1b6c32be8c28b5bfa409e [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8264898 [href_text] => Appendix A Detailed System Check Results [href_description] => SWAGTEK 665024 4G Smart Phone O55665024 O55665024 665024 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => [http_filename] => GetApplicationAttachment.html?id=8264898 [http_size] => 321918 [file_sha256] => 2588c810fdb882e9a2b71d70be5a9caaa0bd6abbd38a3b093818ee852f4658a2 [domain] => document.fccid ) ) Array ( [file_sha256] => 2588c810fdb882e9a2b71d70be5a9caaa0bd6abbd38a3b093818ee852f4658a2 [cleanFccId] => O55665024 [title] => LCS-SAR Lab System Performance Check Results - Appendix A [description] => Detailed system check results from LCS-SAR Lab, including performance checks for various MHz Head frequencies. Report No.: LCSA01025170EB. [brand_name] => LCS [keywords] => ["D750V3", "D835V2", "D1750V2", "D1900V2", "D2450V2", "D2600V2", "750 MHz Head", "835 MHz Head", "1750 MHz Head", "1900 MHz Head", "2450 MHz Head", "2600 MHz Head", "LCSA01025170EB", "055665024"] [intro] =>This document presents the detailed system check results conducted by LCS-SAR Lab, as part of the testing and certification process. The report, identified by number LCSA01025170EB, includes performance checks for various frequencies, specifically focusing on head measurements. The frequencies tested include 750 MHz, 835 MHz, 1750 MHz, 1900 MHz, 2450 MHz, and 2600 MHz. The document outlines the testing parameters, equipment used, and the resulting SAR (Specific Absorption Rate) values obtained during the system performance checks.
The equipment used in the tests includes models such as D750V3, D835V2, D1750V2, D1900V2, D2450V2, and D2600V2. The report provides detailed configurations and measurements, including area scans and zoom scans, to ensure the accuracy and reliability of the SAR assessments. The results are crucial for verifying the compliance of devices with regulatory safety standards.
)
Array ( [0] => Array ( [id] => 8264898 [file_sha256] => [applicationId] => N5rRzoMRWH3cr8K+Vg1tmA== [description] => Appendix A Detailed System Check Results [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => Test Report [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 321918 [submissionDate] => 2025-05-06 00:00:00 [dateAvailable] => 2025-05-06 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 0 [source] => 0 [fccId] => O55665024 [cleanFccId] => O55665024 [exif] => 0 ) )