FCC RF Exposure Report for Generac PWRcell 2 Gateway

RF Exposure

This document presents the FCC RF Exposure evaluation for the Generac PWRcell 2 Gateway, model APCBPGN2101. The evaluation demonstrates compliance with FCC regulations regarding human exposure to radio frequency emissions, specifically under 47 CFR §1.1307(b)(3). The report details the determination of exemption from routine environmental evaluation based on both the 1-mW Test Exemption and SAR-Based Exemption criteria.

The device is classified as a mobile device intended for use with a minimum separation distance of 20 cm. The evaluation includes an assessment of the device's RF output power, considering both WLAN and LTE/NB IoT transmitters. The report also addresses simultaneous transmission scenarios, ensuring that the combined RF exposure remains within acceptable limits. The analysis confirms that the Generac PWRcell 2 Gateway meets the necessary requirements for RF exposure exemption, as outlined in FCC regulations.

The document includes calculations and tables demonstrating compliance with MPE-Based Exemption limits, as well as the simultaneous transmission evaluation. The results indicate that the device operates below the applicable Threshold ERP Limit, satisfying the RF Exposure Exemption requirement. The FCC ID for the device is VDEAPCBPGN2101, and the reference number is 8036A-APCBPGN2101.


File Info : application/pdf, 4 Pages, 394.35KB

Download
Nuance PDF Create
tags: ["Generac PWRcell 2 Gateway", "APCBPGN2101", "VDEAPCBPGN2101", "8036A-APCBPGN2101"]
Array
(
    [0] => Array
        (
            [url_sha] => bd689a809ab977a7db1de44351862585ab4b970fe6eb2e8217c2ca89240d7b81
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8060468
            [href_text] => RF Exposure
            [href_description] => Generac Power Systems Inc. APCBPGN2101 Communication Gateway for PWRcell 2 Smart Disconnect Switch VDEAPCBPGN2101 VDEAPCBPGN2101 apcbpgn2101
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => application/pdf
            [http_filename] => GetApplicationAttachment.html?id=8060468
            [http_size] => 403810
            [file_sha256] => 24f1df9663c3e3469bb45ce71920f57ea13ed0bb464a2ff5044a9d3726b6775a
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => 24f1df9663c3e3469bb45ce71920f57ea13ed0bb464a2ff5044a9d3726b6775a
    [cleanFccId] => VDEAPCBPGN2101
    [title] => FCC RF Exposure Report for Generac PWRcell 2 Gateway
    [description] => FCC RF Exposure evaluation for Generac PWRcell 2 Gateway. The device complies with RF exposure test exemption requirements.
    [brand_name] => Generac Power Systems Inc.
    [keywords] => ["Generac PWRcell 2 Gateway", "APCBPGN2101", "VDEAPCBPGN2101", "8036A-APCBPGN2101"]
    [intro] => 

This document presents the FCC RF Exposure evaluation for the Generac PWRcell 2 Gateway, model APCBPGN2101. The evaluation demonstrates compliance with FCC regulations regarding human exposure to radio frequency emissions, specifically under 47 CFR §1.1307(b)(3). The report details the determination of exemption from routine environmental evaluation based on both the 1-mW Test Exemption and SAR-Based Exemption criteria.

The device is classified as a mobile device intended for use with a minimum separation distance of 20 cm. The evaluation includes an assessment of the device's RF output power, considering both WLAN and LTE/NB IoT transmitters. The report also addresses simultaneous transmission scenarios, ensuring that the combined RF exposure remains within acceptable limits. The analysis confirms that the Generac PWRcell 2 Gateway meets the necessary requirements for RF exposure exemption, as outlined in FCC regulations.

The document includes calculations and tables demonstrating compliance with MPE-Based Exemption limits, as well as the simultaneous transmission evaluation. The results indicate that the device operates below the applicable Threshold ERP Limit, satisfying the RF Exposure Exemption requirement. The FCC ID for the device is VDEAPCBPGN2101, and the reference number is 8036A-APCBPGN2101.

)
Array
(
    [0] => Array
        (
            [id] => 8060468
            [file_sha256] => 
            [applicationId] => B+wgc9tNaHLPqR/uZE9BlA==
            [description] => RF Exposure
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => RF Exposure Info
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 403811
            [submissionDate] => 2025-02-20 00:00:00
            [dateAvailable] => 2025-02-20 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 1
            [source] => 0
            [fccId] => VDEAPCBPGN2101
            [cleanFccId] => VDEAPCBPGN2101
            [exif] => 0
        )

)