Seeed Studio Omi RF Exposure Evaluation Report

RF exposure report

This document presents the RF Exposure Evaluation Report for the Seeed Studio Omi device. The report, identified by number EED32Q82021202, assesses the device's compliance with FCC regulations concerning radio frequency exposure limits. The evaluation was conducted by Centre Testing International Group Co., Ltd, adhering to standards such as 47 CFR Part 1.1307, 1.1310, 2.1091, 2.1093, and KDB 447498 D04. The test results indicate that the Omi device passes the RF exposure requirements.

The report details the product specifications, including the frequency range of 2402MHz to 2480MHz, modulation type (GFSK, π/4DQPSK), and antenna gain of 4.97dBi. The evaluation considers a separation distance of 0.5cm and calculates the MPE ratio to be 0.7043, which is below the limit, confirming compliance. The report concludes that the Seeed Studio Omi device meets the necessary RF exposure safety standards for its intended use.


File Info : application/pdf, 8 Pages, 536.17KB

Download
WPS 文字
tags: ["Omi", "EED32Q82021202", "Z4T-OMI", "Seeed Studio"]
Array
(
    [0] => Array
        (
            [url_sha] => 7f78118f2f5095b62d06ba8c4251a8c3428571676b7176f6a2caf1aa59a5a225
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8093709
            [href_text] => RF exposure report
            [href_description] => Seeed Technology Co., Ltd. OMI Omi Z4T-OMI Z4TOMI omi
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => application/pdf
            [http_filename] => GetApplicationAttachment.html?id=8093709
            [http_size] => 549038
            [file_sha256] => 2393364a384b5dbc96315048ebf2c274fde8ee9c163b3d15b6edb0ebb09faa63
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => 2393364a384b5dbc96315048ebf2c274fde8ee9c163b3d15b6edb0ebb09faa63
    [cleanFccId] => Z4TOMI
    [title] => Seeed Studio Omi RF Exposure Evaluation Report
    [description] => This report evaluates the RF exposure of the Seeed Studio Omi device, ensuring compliance with FCC regulations and safety standards. 
    [brand_name] => Seeed Studio
    [keywords] => ["Omi", "EED32Q82021202", "Z4T-OMI", "Seeed Studio"]
    [intro] => 

This document presents the RF Exposure Evaluation Report for the Seeed Studio Omi device. The report, identified by number EED32Q82021202, assesses the device's compliance with FCC regulations concerning radio frequency exposure limits. The evaluation was conducted by Centre Testing International Group Co., Ltd, adhering to standards such as 47 CFR Part 1.1307, 1.1310, 2.1091, 2.1093, and KDB 447498 D04. The test results indicate that the Omi device passes the RF exposure requirements.

The report details the product specifications, including the frequency range of 2402MHz to 2480MHz, modulation type (GFSK, π/4DQPSK), and antenna gain of 4.97dBi. The evaluation considers a separation distance of 0.5cm and calculates the MPE ratio to be 0.7043, which is below the limit, confirming compliance. The report concludes that the Seeed Studio Omi device meets the necessary RF exposure safety standards for its intended use.

)
Array
(
    [0] => Array
        (
            [id] => 8093709
            [file_sha256] => 
            [applicationId] => xzmV23AGWCT4+4yBdQDrPA==
            [description] => RF exposure report
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => RF Exposure Info
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 549040
            [submissionDate] => 2025-03-05 00:00:00
            [dateAvailable] => 2025-03-05 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 1
            [source] => 0
            [fccId] => Z4T-OMI
            [cleanFccId] => Z4TOMI
            [exif] => 0
        )

)