The Liquiline CM42B is a two-wire transmitter designed for field use, compatible with both digital (Memosens) and analog sensors. This brief operating instruction provides essential information for safe and effective use. It covers safety guidelines, product description, mounting procedures, electrical connections, operation options, system integration, maintenance, and technical data.
The device supports measurement of pH/ORP, conductivity (conductive and inductive), and dissolved oxygen (amperometric and optical). Operation is possible via on-site display, SmartBlue app, or PLC control station (HART). Safety is paramount, with warnings and cautions throughout the document. Proper installation, electrical connection, and maintenance are crucial for optimal performance and safety.
The document also includes detailed instructions for mounting, wiring, and connecting sensors, as well as troubleshooting tips. It emphasizes the importance of using appropriate tools and following safety regulations to prevent damage to the device or injury to personnel. This guide serves as a quick reference for users to understand the basic functions and safety aspects of the Liquiline CM42B.
Array ( [0] => Array ( [url_sha] => 129bb351040b10e357b7c35388f5cf8d73328434b1b264240c6d0d33d5184ff6 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8074900 [href_text] => User Manual [href_description] => Endress and Hauser Conducta GmbH and Co KG CM42B Two-wire transmitter 2AKGY-CM42B 2AKGYCM42B cm42b [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8074900 [http_size] => 4032899 [file_sha256] => 1dfae573f319576f74a847a8d9c7f9b0200ce078fa8f6062013f76de5507c086 [domain] => manual.fccid ) [1] => Array ( [url_sha] => 4a836502fcdbbb12619ca26ad7ef695590fe6e80e562f47a56a4085557266924 [source] => scalei [url] => https://bdih-download.endress.com/files/DLA/005056A500261EDFB5FE628E70FD4F14/KA01730CEN_0124-00.pdf [href_text] => Liquiline CM42B [href_description] => [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => KA01730CEN_0124-00.pdf [http_size] => 4032901 [file_sha256] => 1dfae573f319576f74a847a8d9c7f9b0200ce078fa8f6062013f76de5507c086 [domain] => bdih-download.endress.com ) [2] => Array ( [url_sha] => 4a836502fcdbbb12619ca26ad7ef695590fe6e80e562f47a56a4085557266924 [source] => downloader [url] => https://bdih-download.endress.com/files/DLA/005056A500261EDFB5FE628E70FD4F14/KA01730CEN_0124-00.pdf [href_text] => Copy Link [href_description] => 2-wire transmitter for pH, ORP, conductivity or dissolved oxygen | Endress+Hauser [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => KA01730CEN_0124-00.pdf [http_size] => 4032901 [file_sha256] => 1dfae573f319576f74a847a8d9c7f9b0200ce078fa8f6062013f76de5507c086 [domain] => bdih-download.endress.com ) ) Array ( [file_sha256] => 1dfae573f319576f74a847a8d9c7f9b0200ce078fa8f6062013f76de5507c086 [cleanFccId] => 2AKGYCM42B [title] => Liquiline CM42B: Brief Operating Instructions [description] => A brief guide to the Liquiline CM42B two-wire transmitter, covering safety, installation, operation, and technical data. [brand_name] => Endress+Hauser [keywords] => ["Liquiline CM42B", "CM42B", "BA02380C", "SD03215C", "IEC 60558-2-16", "IEC 62368-1", "IEC 61010-1", "IEC 60529", "IP66", "IP67"] [intro] =>The Liquiline CM42B is a two-wire transmitter designed for field use, compatible with both digital (Memosens) and analog sensors. This brief operating instruction provides essential information for safe and effective use. It covers safety guidelines, product description, mounting procedures, electrical connections, operation options, system integration, maintenance, and technical data.
The device supports measurement of pH/ORP, conductivity (conductive and inductive), and dissolved oxygen (amperometric and optical). Operation is possible via on-site display, SmartBlue app, or PLC control station (HART). Safety is paramount, with warnings and cautions throughout the document. Proper installation, electrical connection, and maintenance are crucial for optimal performance and safety.
The document also includes detailed instructions for mounting, wiring, and connecting sensors, as well as troubleshooting tips. It emphasizes the importance of using appropriate tools and following safety regulations to prevent damage to the device or injury to personnel. This guide serves as a quick reference for users to understand the basic functions and safety aspects of the Liquiline CM42B.
)
Array ( [0] => Array ( [id] => 8074900 [file_sha256] => [applicationId] => mUobTHVGhS3xGR87/plLPA== [description] => User Manual [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => Users Manual [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 4032901 [submissionDate] => 2025-02-26 00:00:00 [dateAvailable] => 2025-02-26 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => 2AKGY-CM42B [cleanFccId] => 2AKGYCM42B [exif] => 0 ) )