This document presents a comprehensive test report focusing on out-of-band emissions and conducted output power measurements. The tests were conducted by BCTC to ensure compliance with FCC regulations, specifically FCC §15.407, for devices operating in the U-NII-1 (5180-5240MHz) and U-NII-3 (5745-5825MHz) frequency bands. The report details the test setup, procedures, and results obtained for various operating modes, including a, n20, n40, ac20, ac40, ax20, and ax40.
The out-of-band emissions were evaluated to ensure that emissions outside the designated frequency bands are adequately attenuated, adhering to the specified limits. Conducted output power measurements were performed to verify that the device's transmission power remains within the permissible levels. The report includes detailed data tables and spectrum analyzer plots illustrating the test results for each mode and frequency. All measurements were conducted under controlled laboratory conditions, and the equipment used was calibrated to ensure accuracy and reliability. The results presented in this report demonstrate the device's compliance with the applicable regulatory requirements.