This document contains calibration reports for a COMOSAR Dosimetric E-Field Probe and a COMOSAR SAR Reference Dipole, both calibrated by MVG (Microwave Vision Group). The E-Field Probe, serial number 3823-EPGO-435, model SSE2, was calibrated on 07/11/2024. The SAR Reference Dipole, serial number SN 13/15 DIP 2G450-364, model SID2450, was calibrated on 08/20/2023.
The E-Field Probe calibration report details the method and results of an accredited calibration performed using the CALIPROBE test bench, ensuring its suitability for use with a MVG COMOSAR system. The report includes information on sensitivity, linearity, isotropy, boundary effect, and probe modulation response. The SAR Reference Dipole calibration report presents the method and results from an accredited calibration performed in MVG using the COMOSAR test bench. All calibration results are traceable to national metrology institutions.
Both reports ensure that the devices meet the requirements set forth by the IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards. The calibration results are essential for accurate SAR measurements and system validations.
Array ( [0] => Array ( [url_sha] => 5664c2c9d450c2b34118b148a438a359c48a4b033fa9cd9baddb6b68f55bae17 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8101541 [href_text] => SAR Exhibit for the Calibration Certificate [href_description] => Shenzhen Yuwan Network Technology Co., Ltd Q1K Kids Tablet 2BNIH-Q1K 2BNIHQ1K q1k [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8101541 [http_size] => 1179582 [file_sha256] => 155467ef5db87c6d2ce410638c01440961c56cfe8fe9b2ffbb2ac4d9cc5dbb07 [domain] => document.fccid ) [1] => Array ( [url_sha] => 9b986118aa6d9fb1943e203384f2c8156a3fc85b41beb342f1b55f25f258f836 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8141078 [href_text] => RF Exposure Info 1 [href_description] => Hong Kong Lute Technology Co., Limited WN02 White Noise Machine 2A6UA-WN02 2A6UAWN02 wn02 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => [http_filename] => GetApplicationAttachment.html?id=8141078 [http_size] => 1179582 [file_sha256] => 155467ef5db87c6d2ce410638c01440961c56cfe8fe9b2ffbb2ac4d9cc5dbb07 [domain] => document.fccid ) ) Array ( [file_sha256] => 155467ef5db87c6d2ce410638c01440961c56cfe8fe9b2ffbb2ac4d9cc5dbb07 [cleanFccId] => 2BNIHQ1K [title] => COMOSAR E-Field Probe and SAR Reference Dipole Calibration [description] => Accredited calibration reports for COMOSAR E-Field Probe and SAR Reference Dipole, ensuring accurate measurements and compliance with standards. [brand_name] => MVG (Microwave Vision Group) [keywords] => ["3823-EPGO-435", "SSE2", "ACR.193.11.24.BES.B", "ACR.104.1.23.SATU.A", "SN 13/15 DIP 2G450-364", "SID2450", "COMOSAR", "Dosimetric E-Field Probe", "SAR Reference Dipole", "#2-6789", "#2-6814"] [intro] =>This document contains calibration reports for a COMOSAR Dosimetric E-Field Probe and a COMOSAR SAR Reference Dipole, both calibrated by MVG (Microwave Vision Group). The E-Field Probe, serial number 3823-EPGO-435, model SSE2, was calibrated on 07/11/2024. The SAR Reference Dipole, serial number SN 13/15 DIP 2G450-364, model SID2450, was calibrated on 08/20/2023.
The E-Field Probe calibration report details the method and results of an accredited calibration performed using the CALIPROBE test bench, ensuring its suitability for use with a MVG COMOSAR system. The report includes information on sensitivity, linearity, isotropy, boundary effect, and probe modulation response. The SAR Reference Dipole calibration report presents the method and results from an accredited calibration performed in MVG using the COMOSAR test bench. All calibration results are traceable to national metrology institutions.
Both reports ensure that the devices meet the requirements set forth by the IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards. The calibration results are essential for accurate SAR measurements and system validations.
)
Array ( [0] => Array ( [id] => 8141078 [file_sha256] => [applicationId] => TuYsZcquteNB942Vz0RS/A== [description] => RF Exposure Info 1 [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => None [submissionDate] => 2025-03-24 00:00:00 [dateAvailable] => 2025-03-24 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 0 [source] => 0 [fccId] => 2A6UA-WN02 [cleanFccId] => 2A6UAWN02 [exif] => 0 ) [1] => Array ( [id] => 8101541 [file_sha256] => [applicationId] => gy9Gm6QG92BdYiQC1eR+GA== [description] => SAR Exhibit for the Calibration Certificate [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 1179584 [submissionDate] => 2025-03-07 00:00:00 [dateAvailable] => 2025-03-07 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => 2BNIH-Q1K [cleanFccId] => 2BNIHQ1K [exif] => 0 ) )