This document provides a comprehensive overview of the parameters and calibration data for the EX3DV4 probe with serial number SN:3857. It includes detailed information about the probe's sensor model, including the C1, C2, alpha, T1, T2, T3, T4, T5, and T6 parameters for each sensor (X, Y, and Z). The document also outlines other crucial probe parameters such as sensor arrangement, connector angle, surface detection modes, overall length, body diameter, tip length, and recommended measurement distance from the surface.
Furthermore, the document presents the calibration parameters determined in head tissue simulating media for various frequencies, including relative permittivity, conductivity, ConvF values for X, Y, and Z, Alpha, and Depth. A detailed appendix on modulation calibration parameters is included, listing various communication systems, their corresponding groups, PAR (Peak-to-Average Ratio) values, and associated uncertainties. This information is essential for accurate SAR (Specific Absorption Rate) measurements and simulations using the EX3DV4-SN:3857 probe.
Array ( [0] => Array ( [url_sha] => 6724b40da9c4cb5d3c3a213c2733901582e263df2af5831656ca9d93ff16b504 [source] => fccid [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8085894 [href_text] => 2BEWXTYST20_TestRpt_SAR_Appendix C_Part2-2 [href_description] => Zhejiang Lingzhu Technology Co., Ltd. TYST20 4G Locator 2BEWXTYST20 2BEWXTYST20 tyst20 [http_status] => 200 [http_lastmod] => 0000-00-00 00:00:00 [http_contenttype] => application/pdf [http_filename] => GetApplicationAttachment.html?id=8085894 [http_size] => 4062630 [file_sha256] => 110825340d31f697cb742436202fbd744c8129e6a4cff33b80aeba625b146b56 [domain] => document.fccid ) ) Array ( [file_sha256] => 110825340d31f697cb742436202fbd744c8129e6a4cff33b80aeba625b146b56 [cleanFccId] => 2BEWXTYST20 [title] => EX3DV4-SN:3857 Probe Parameters and Modulation Calibration [description] => Detailed parameters of the EX3DV4-SN:3857 probe, including sensor model parameters, probe parameters, and modulation calibration. [brand_name] => SPEAG [keywords] => ["EX3DV4", "SN:3857", "EX-3857_Jan24"] [intro] =>This document provides a comprehensive overview of the parameters and calibration data for the EX3DV4 probe with serial number SN:3857. It includes detailed information about the probe's sensor model, including the C1, C2, alpha, T1, T2, T3, T4, T5, and T6 parameters for each sensor (X, Y, and Z). The document also outlines other crucial probe parameters such as sensor arrangement, connector angle, surface detection modes, overall length, body diameter, tip length, and recommended measurement distance from the surface.
Furthermore, the document presents the calibration parameters determined in head tissue simulating media for various frequencies, including relative permittivity, conductivity, ConvF values for X, Y, and Z, Alpha, and Depth. A detailed appendix on modulation calibration parameters is included, listing various communication systems, their corresponding groups, PAR (Peak-to-Average Ratio) values, and associated uncertainties. This information is essential for accurate SAR (Specific Absorption Rate) measurements and simulations using the EX3DV4-SN:3857 probe.
)
Array ( [0] => Array ( [id] => 8085894 [file_sha256] => [applicationId] => j/cHWAuO85XYu0VJ5lka4g== [description] => 2BEWXTYST20_TestRpt_SAR_Appendix C_Part2-2 [shortTermConfidential] => No [permanentConfidential] => No [supercede] => No [exhibitType] => RF Exposure Info [fileType] => Adobe Acrobat PDF [displayType] => pdf [fileSize] => 4062632 [submissionDate] => 2025-03-03 00:00:00 [dateAvailable] => 2025-03-03 00:00:00 [creationDate] => [producer] => [modDate] => [title] => [creator] => [author] => [pages] => [realSize] => [html] => 0 [png] => 0 [txt] => 0 [version] => 1 [source] => 0 [fccId] => 2BEWXTYST20 [cleanFccId] => 2BEWXTYST20 [exif] => 0 ) )