Logitech Wireless Headset SAR Test Report

RF Exposure Info (SAR)_rev

This SAR (Specific Absorption Rate) test report details the evaluation of the Logitech wireless headset, model A00195, for RF exposure compliance. The testing was conducted by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch-Lin Kou Laboratories, and the equipment was found to comply with the relevant FCC and IEEE standards.

The report includes a comprehensive overview of the measurement system, including the SPEAG DASY6 system, probes, data acquisition electronics, and phantoms used. It also outlines the SAR measurement procedure, covering area scans, zoom scans, and power drift monitoring. The EUT (Equipment Under Test) configuration and settings are described, along with the tissue verification and system validation processes.

The maximum SAR value recorded for the head exposure condition was 0.16 W/kg. The report also includes information on the calibration of test equipment, measurement uncertainty, and the testing laboratories involved. Appendices provide SAR plots of system verification and SAR measurement, as well as calibration certificates for the probe and dipole.


File Info : application/pdf, 24 Pages, 1.05MB

Download
Microsoft Word 2019 Microsoft Word 2019
tags: ["A00195", "Wireless headset", "JNZA00195", "Logitech", "logi", "logitech G", "G", "TW0003"]
Array
(
    [0] => Array
        (
            [url_sha] => d7a4ae7cac9a1e55790bdec42cdbf624dc72515df24b2b71ca9327a363c636b9
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8125016
            [href_text] => RF Exposure Info (SAR)_rev
            [href_description] => Logitech Far East Ltd A00195 Wireless Headset JNZA00195 JNZA00195 a00195
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => application/pdf
            [http_filename] => GetApplicationAttachment.html?id=8125016
            [http_size] => 1101941
            [file_sha256] => 0c4d4d28802cb7fc00701eff6133c91c39d8d0819e324fe9999bd42532a8c796
            [domain] => document.fccid
        )

    [1] => Array
        (
            [url_sha] => 3bdb3244841bd902a536b673cb46c5dbe3b282dfc5f2fc58e294b0730ed8742d
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8125063
            [href_text] => RF Exposure Info (SAR)_rev
            [href_description] => Logitech Far East Ltd A00195 Wireless Headset JNZA00195 JNZA00195 a00195
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => application/pdf
            [http_filename] => GetApplicationAttachment.html?id=8125063
            [http_size] => 1101941
            [file_sha256] => 0c4d4d28802cb7fc00701eff6133c91c39d8d0819e324fe9999bd42532a8c796
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => 0c4d4d28802cb7fc00701eff6133c91c39d8d0819e324fe9999bd42532a8c796
    [cleanFccId] => JNZA00195
    [title] => Logitech Wireless Headset SAR Test Report
    [description] => SAR test report for the Logitech wireless headset, model A00195, tested by Bureau Veritas. Compliant with FCC and IEEE standards.
    [brand_name] => Logitech
    [keywords] => ["A00195", "Wireless headset", "JNZA00195", "Logitech", "logi", "logitech G", "G", "TW0003"]
    [intro] => 

This SAR (Specific Absorption Rate) test report details the evaluation of the Logitech wireless headset, model A00195, for RF exposure compliance. The testing was conducted by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch-Lin Kou Laboratories, and the equipment was found to comply with the relevant FCC and IEEE standards.

The report includes a comprehensive overview of the measurement system, including the SPEAG DASY6 system, probes, data acquisition electronics, and phantoms used. It also outlines the SAR measurement procedure, covering area scans, zoom scans, and power drift monitoring. The EUT (Equipment Under Test) configuration and settings are described, along with the tissue verification and system validation processes.

The maximum SAR value recorded for the head exposure condition was 0.16 W/kg. The report also includes information on the calibration of test equipment, measurement uncertainty, and the testing laboratories involved. Appendices provide SAR plots of system verification and SAR measurement, as well as calibration certificates for the probe and dipole.

)
Array
(
    [0] => Array
        (
            [id] => 8125016
            [file_sha256] => 
            [applicationId] => UCTDsclV4kID2JIxwZRyOA==
            [description] => RF Exposure Info (SAR)_rev
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => RF Exposure Info
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 1101943
            [submissionDate] => 2025-03-18 00:00:00
            [dateAvailable] => 2025-03-18 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 1
            [source] => 0
            [fccId] => JNZA00195
            [cleanFccId] => JNZA00195
            [exif] => 0
        )

)