This document presents the RF exposure compliance report for the Power Combo Charging Tower, model i113, and its derivative models including i113Pro, i113Max, PowerSync-103, RN103, and PD-105W. The report details the test setup, procedure, and results obtained during the RF exposure assessment. The device was tested in various modes, including wireless charging for phones and earbuds, with different battery status levels. Measurements were taken at a distance of 20 cm from the device to assess the E-field and H-field strengths.
The test results demonstrate that the device complies with the limits for Maximum Permissible Exposure (MPE) as specified in FCC regulations. The report includes a list of test instruments used, along with their calibration dates. The device supports simultaneous transmission with multiple antennas, and the combined MPE values are within the acceptable limits. The test setup and procedure followed the guidelines outlined in KDB 680106 D01 Wireless Power Transfer v04. The report concludes that the Power Combo Charging Tower meets the RF exposure requirements for mobile devices.
File Info : application/pdf, 7 Pages, 857.36KB