EX3DV4 Calibration Certificate: SN:7544 for Dosimetric E-Field Probes

Appendix C Calibration certificate 1

This document presents the calibration certificate for the EX3DV4 probe with serial number 7544, designed for dosimetric E-field probe applications. The calibration was performed by Schmid & Partner Engineering AG, an accredited calibration laboratory, and is traceable to national standards. The calibration procedure adheres to several QA standards, including QA CAL-01.v10, QA CAL-12.v10, QA CAL-14.v7, QA CAL-23.v6, and QA CAL-25.v8.

The certificate details the probe's performance characteristics, including sensitivity, linearity, and isotropy, across a range of frequencies. It also includes information on the sensor model parameters, calibration factors in head tissue simulating media, and modulation calibration parameters for various communication systems. The reported uncertainty of measurement is stated as the standard uncertainty multiplied by the coverage factor k=2, corresponding to a coverage probability of approximately 95%.

This certificate is essential for ensuring the accuracy and reliability of measurements performed using the EX3DV4 probe in compliance with regulatory requirements and industry best practices.


File Info : application/pdf, 32 Pages, 4.79MB

Download
DocuCentre S2520 DocuCentre S2520
tags: ["EX3DV4", "SN:7544", "SCS 0108", "QA CAL-01.v10", "QA CAL-12.v10", "QA CAL-14.v7", "QA CAL-23.v6", "QA CAL-25.v8"]
Array
(
    [0] => Array
        (
            [url_sha] => bd9428434853e9142697b069c208563d01d7991880ac0f593bb1f2673fe70006
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8094677
            [href_text] => Appendix C Calibration certificate 1
            [href_description] => The Light Phone Inc. GOLIGHT3  2AIBC-GOLIGHT3 2AIBCGOLIGHT3 golight3
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => application/pdf
            [http_filename] => GetApplicationAttachment.html?id=8094677
            [http_size] => 5023999
            [file_sha256] => 00742e0cf7cd8eca2c24204777d7463cd4019810a64800f71705a1470eabfdd7
            [domain] => document.fccid
        )

    [1] => Array
        (
            [url_sha] => a5a2859162de9f9188cac3f1d6d125a191b07031a87cbb09e6d72d0535b9e6e0
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8095015
            [href_text] => SAR test report appendix C-1
            [href_description] => The Light Phone Inc. GOLIGHT3 Light Phone III 2AIBC-GOLIGHT3 2AIBCGOLIGHT3 golight3
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => application/pdf
            [http_filename] => GetApplicationAttachment.html?id=8095015
            [http_size] => 5023999
            [file_sha256] => 00742e0cf7cd8eca2c24204777d7463cd4019810a64800f71705a1470eabfdd7
            [domain] => document.fccid
        )

    [2] => Array
        (
            [url_sha] => 4b768b52398ff923af59c69e12e2b84bc3f6ba211862aa6e07fab4fc702da752
            [source] => fccid
            [url] => https://apps.fcc.gov/eas/GetApplicationAttachment.html?id=8094951
            [href_text] => Appendix C Calibration Certificate R00 1
            [href_description] => The Light Phone Inc. GOLIGHT3 Light Phone III 2AIBC-GOLIGHT3 2AIBCGOLIGHT3 golight3
            [http_status] => 200
            [http_lastmod] => 0000-00-00 00:00:00
            [http_contenttype] => application/pdf
            [http_filename] => GetApplicationAttachment.html?id=8094951
            [http_size] => 5023999
            [file_sha256] => 00742e0cf7cd8eca2c24204777d7463cd4019810a64800f71705a1470eabfdd7
            [domain] => document.fccid
        )

)
Array
(
    [file_sha256] => 00742e0cf7cd8eca2c24204777d7463cd4019810a64800f71705a1470eabfdd7
    [cleanFccId] => 2AIBCGOLIGHT3
    [title] => EX3DV4 Calibration Certificate: SN:7544 for Dosimetric E-Field Probes
    [description] => Calibration certificate for EX3DV4 probe (SN:7544) used in dosimetric E-field measurements. Accredited by the Swiss Accreditation Service (SAS).
    [brand_name] => Schmid & Partner Engineering AG
    [keywords] => ["EX3DV4", "SN:7544", "SCS 0108", "QA CAL-01.v10", "QA CAL-12.v10", "QA CAL-14.v7", "QA CAL-23.v6", "QA CAL-25.v8"]
    [intro] => 

This document presents the calibration certificate for the EX3DV4 probe with serial number 7544, designed for dosimetric E-field probe applications. The calibration was performed by Schmid & Partner Engineering AG, an accredited calibration laboratory, and is traceable to national standards. The calibration procedure adheres to several QA standards, including QA CAL-01.v10, QA CAL-12.v10, QA CAL-14.v7, QA CAL-23.v6, and QA CAL-25.v8.

The certificate details the probe's performance characteristics, including sensitivity, linearity, and isotropy, across a range of frequencies. It also includes information on the sensor model parameters, calibration factors in head tissue simulating media, and modulation calibration parameters for various communication systems. The reported uncertainty of measurement is stated as the standard uncertainty multiplied by the coverage factor k=2, corresponding to a coverage probability of approximately 95%.

This certificate is essential for ensuring the accuracy and reliability of measurements performed using the EX3DV4 probe in compliance with regulatory requirements and industry best practices.

)
Array
(
    [0] => Array
        (
            [id] => 8094677
            [file_sha256] => 
            [applicationId] => E0XYqQuJXxshPFaDgmTksQ==
            [description] => Appendix C Calibration certificate 1
            [shortTermConfidential] => No
            [permanentConfidential] => No
            [supercede] => No
            [exhibitType] => RF Exposure Info
            [fileType] => Adobe Acrobat PDF
            [displayType] => pdf
            [fileSize] => 5024001
            [submissionDate] => 2025-03-05 00:00:00
            [dateAvailable] => 2025-03-05 00:00:00
            [creationDate] => 
            [producer] => 
            [modDate] => 
            [title] => 
            [creator] => 
            [author] => 
            [pages] => 
            [realSize] => 
            [html] => 0
            [png] => 0
            [txt] => 0
            [version] => 0
            [source] => 0
            [fccId] => 2AIBC-GOLIGHT3
            [cleanFccId] => 2AIBCGOLIGHT3
            [exif] => 0
        )

)